2019-9-28  Carrier Thermostat Wiring. Recently, we just completed an In-depth Thermostat Wiring DIY Guide which covers many wiring situations. Once you select a Carrier thermostat and want to wire it by yourself, remember to add this guide to your favorite list. I am wanting to replace my old theromstat with a programmable theromstat. However, I have run into a slight issue. The old thermostat only has two wires coming out of the wall and three wires ( yellow, red, white) tied to the mercury. The one white wire is going back into a radial button that states longer on it and some numbers. The two wires that are coming out of the wall that are tied to. View and Download Carrier Thermostat installation, start-up, and operating instructions manual online. Carrier Thermostat User Manual. Thermostat Thermostat pdf manual download. Also for: Ac01-b. Carrier offers thermostats and controls for the highest degree of climate control, from temperature to humidity, while staying energy efficient. 2013-8-2  Carrier’s 7-day, 5/2-day, or 1-day programmable commer-cial thermostat control is a wall-mounted, low-voltage control which provides temperature control in either a single unit or a two-piece unit. The 33CS2PPRH-01 will provide both temper-ature.

Download 304 Carrier Thermostat PDF manuals. User manuals, Carrier Thermostat Operating guides and Service manuals. Carrier Thermostat Tollison864. Unsubscribe from Tollison864? Mistakes made when hooking up a thermostat Avoid them watch - Duration: 5:43. Environc 892,298 views.

Advertising

Close to or in a frequently used room, preferably on an inside
partitioning wall.

On a section of wall without pipes or duct work.

Thermostat should NOT be mounted:

Close to a window, on an outside wall, or next to a door leading
to the outside.

Exposed to direct light and heat from a lamp, sun, fireplace, or
other temperature-radiating object which may cause a false
reading.

Close to or in direct airflow from supply registers and return-air
grilles.

In areas with poor air circulation, such as behind a door or in
an alcove.

Step 2—Set DIP Switches

There is a 4 section DIP switch within the thermostat which must
be properly set by the installer. It is easiest to set these 4 switches
before the thermostat is mounted to the wall, so STOP and
complete the following steps:

1. Open hinged thermostat cover.

2. Remove cover completely by snapping it apart at hinge.

3. Open thermostat by pressing back half of the right end of

plastic case inward while, at the same time, pulling front and
back halves apart at the right end. The 2 halves will swing
apart.

4. Snap hinge apart to completely separate the 2 halves.

5. Switches are located in upper right corner of circuit board. To

change switch position, use corner of a small screwdriver to
slide switch to opposite position.

6. After switches have been set, do not reassemble the 2 halves.

The rear plastic will be first mounted to wall.

Switch A - Zoning Select (Active on all models)

This switch selects or defeats the 4 cycles per hour limit and a
5-minute compressor timeguard. These timers MUST be enabled
for normal operation and disabled for zoning applications. (In
zoning applications the zone control center performs these timing
functions.)
TO SET:
OFF— for normal operation. This is the factory default.
ON—for zoned installations ONLY.

Switch B - Setback Recovery (Active on all models)

Selects between normal and smart recovery from setback. Normal
recovery changes to the new setpoint at the programmed time.
Smart recovery, which is active in heating mode only, starts earlier
and adjusts the setpoint slowly so that room temperature will arrive
at the programmed temperature at the programmed time.
TO SET:
OFF—for smart recovery. This is the factory default.
ON—for normal recovery.

Switch C - HP/AC Select (Active on HP and 2S models only)

Use to select between AC and HP installations. HP and 2S models
have an extra relay to control the HP reversing valve. When a HP
thermostat is placed in the AC mode, this extra relay is converted
to a second stage heat output. This allows thermostat control of
2-stage furnaces or 2-stage strip heat with AC systems. (AC mode
also uses W rather than Y for first-stage heat.)
TO SET:
OFF—for HP applications. Extra relay controls reversing valve.
This is factory default.
ON—for AC applications. Extra output can be used for 2-stage
heat.

Switch D - Intelligent Heat Staging Select

(Active on 2S models only)

This switch converts a 2-speed heat pump thermostat with 1 stage
of auxiliary heat into a 1-speed heat pump thermostat with 3 stages
of auxiliary heat for comfortable leaving air temperature. It
requires selected heaters with 2:1 ratio element sizes plus an FK,
FV, 40FKA fan coil. Refer to variable-speed fan coil literature for
details.
TO SET:
OFF—for normal 2-speed operation. This is factory default.
ON—for intelligent 3-stage heat with FK, FV, 40FKA fan coil.

Step 3—Install Thermostat

Before installing thermostat, turn off all power to unit. There
may be more than 1 power disconnect. Electrical shock can
cause personal injury or death.

1. Turn OFF all power to unit.

2. If an existing thermostat is being replaced:

a. Remove existing thermostat from wall.

b. Disconnect wires from existing thermostat, 1 at a time. Be

careful not to allow wires to fall back into the wall.

c. As each wire is disconnected, record wire color and

terminal marking.

d. Discard or recycle old thermostat.

NOTE:

Mercury is a hazardous waste and MUST be disposed of

Carrier Thermostat Programming Instructions

properly.

3. Open thermostat rear door (mounting base) to expose mount-

ing holes. The base can be removed to simplify mounting.
Snap apart carefully at hinge to separate mounting base from
remainder of thermostat.

4. Route thermostat wires through large hole in mounting base.

Level mounting base against wall (for aesthetic value
only—thermostat need not be leveled for proper operation)
and mark wall through 2 mounting holes.

5. Drill two 3/16-in. mounting holes in wall where marked.

6. Secure mounting base to wall with 2 screws and anchors

provided, (additional anchoring holes available for more
secure mounting if needed) making sure all wires extend
through hole in mounting base.

7. Adjust length and routing of each wire to reach proper

terminal and connector block on mounting base with 1/4 in. of
extra wire. Strip only 1/4 in. of insulation from each wire to
prevent adjacent wires from shorting together when con-
nected.

8. Match and connect equipment wires to proper terminals of the

connector blocks. (See Table 1, and Fig. 2 through 24.) Both
R and C must be connected for proper thermostat operation.

Improper wiring or installation may damage the thermostat.
Check to make sure wiring is correct before proceeding with
installation or turning on unit.

9. Push any excess wire into wall and against mounting base.

Do not include any other items with the defective Product. The Product covered by this limited warranty and proven to be defective upon inspection will be repaired and returned to you without charge by the authorized service center. (1) Large/Fine: Approx. Canon eos 500d manual. Any Product received by the authorized service center that is not covered by the limited warranty will be returned unrepaired, or at the discretion of the authorized service provider, you may receive a written estimate of repair at such cost as the service center may establish from time to time.This limited warranty gives you specific legal rights, and you may also have other rights, which vary from state to state (or province to province in Canada).The battery pack packaged with the Product carries a separate ninety (90) day limited warranty.

Seal hole in wall to prevent air leaks. Leaks can affect
operation.

10. Snap hinge back together.

11. Close thermostat assembly making sure pins on back of circuit

board align with sockets in connector.